THIS SERVICE AID DISKETTE REPORTS THE SOURCE OF OS/2 TRAP0002 ERRORS ON SOME PS/2 SYSTEMS USING THE OS/2 OPERATING SYSTEM. THE UTILITY IS APPLICABLE ONLY TO ALL MODELS OF THE FOLLOWING SYSTEMS: 8565, 8570, 8573(P70, P75), 8580. PRIOR TO USE OF THIS UTILITY, INSURE ANY APPLICABLE HARDWARE CHANGES (ECA's) HAVE BEEN INSTALLED. CONSULT APPROPRIATE TECHNICAL BULLETINS. IT IS RECOMMENDED THAT OS/2 1.2 HAVE CSD 4098 OR HIGHER INSTALLED. CUSTOMER SHOULD VERIFY PROPER DEVICE DRIVER, ADF FILES, AND LATEST ABIOS PATCHES ARE INSTALLED. DIAGNOSTICS SHOULD BE RUN PRIOR TO ANY HARDWARE CHANGES. THE UTILITY WILL DISPLAY THE CONTENTS OF THE NMI ERROR LOG. THE 4 SOURCES OF TRAP0002 ERRORS ARE AS FOLLOWS: 110 SYSTEM BOARD MEMORY ERROR. 111 I/O CHANNEL CHECK. 112 WATCHDOG TIMER TIMEOUT. 113 DMA TIMEOUT. You will find the file for this diskette in file directory #4, with a file name of SERVAID.TG0.