Softpaq Solution: SP1020 File Name: CPQHLTH.DLL Title: For Compaq Insight Manager under Windows NT 3.5, corrects empty configuration screen Version: Insight Management Agents ver 2.30 _______________________________________________________________________ CATEGORY: Software Solution EFFECTIVE DATE: 7-12-94 PRODUCTS AFFECTED: ProLiant 4000 with memory board installed OPERATING SYSTEM: Windows NT 3.5 - NT Agent release 2.30 SYSTEM CONFIGURATION: Any ProLiant 4000 system with an optional memory expansion board installed. SUPERSEDES: Not applicable DESCRIPTION: When configuration is selected on Compaq Insight Manager, the screen will come up with no data in it. Compaq Insight Manager may also hang when trying to get the configuration data screen. This problem is due to the NT Insight Agent running on the server reporting bad configuration information to the Insight Management console. HOW TO USE: 1. After downloading SoftPaq, change to the download directory. For example: C:> CD \CPQ If downloaded in zipped format (.ZIP), unzip the file to create an executable: C:\CPQ> PKUNZIP SP1020 2. From that drive and directory, run the SoftPaq utility to unbind the primary files: C:\CPQ> SP1020 [ENTER] The following files should be created: CPQHLTH.DLL 3. Perform the following steps on the monitored server, NOT on the management console. 1) Stop NT Insignt Management Agents via Services control panel applet. 2) Copy CPQHLTH.DLL, contained in Softpaq, to the following directory: :%windir%\system32\cpqmgmt where :%windir% is the Windows NT directory. 3) Restart NT Insight Management Agents via Services control panel applet.