Softpaq Solution: SP1021 File Name: CPQHLTH.DLL Title: For Compaq Insight Manager under OS/2, corrects empty configuration screen Version: Compaq Insight Management Agents for OS/2 version 2.30 _______________________________________________________________________ CATEGORY: Software Solution EFFECTIVITY DATE: 11-17-94 PRODUCTS AFFECTED: ProLiant 4000 with memory board installed. OPERATING SYSTEM: OS/2 2.x - Compaq Insight Agents version 2.30 SYSTEM CONFIGURATION: Any ProLiant 4000 system with an optional memory expansion board installed. SUPERSEDES: N/A DESCRIPTION: When configuration is selected on Compaq Insight Manager, the screen will come up with no data in it. Compaq Insight Manager may also hang when trying to get the configuration data screen. This problem is due to the Insight Agent running on the server reporting bad configuration information to the Insight Management console. HOW TO USE: 1. After downloading SoftPaq, change to the download directory. For example: C:> CD \CPQ If downloaded in zipped format (.ZIP), unzip the file to create an executable: C:\CPQ> PKUNZIP SP1021 2. From that drive and directory, run the SoftPaq utility to unbind the primary files: C:\CPQ> SP1021 [ENTER] The following files should be created: CPQHLTH.DLL 3. Perform the following steps on the monitored server, NOT on the management console. 1) Stop Compaq Insight Management Agents on the OS/2 server. To stop the Insight Agents, locate the CPQMGMT.EXE window. Type CRTL-C to stop the Insight Agents. 2) Copy CPQHLTH.DLL, contained in this Softpaq, to the Insight Agents directory. The default is C:\CPQAGENT. Check the CONFIG.SYS PATH if unsure. 3) Shutdown OS/2 and reset the server for changes to take effect.