Power Switching System (260-0138) Specifications Faxback Doc. # 2552 Power Requirement 120 VAC, 60 Hz, 15Amp Max. Capacity 5 Outlets Power Rating: Computer 5 Amps Max. 600 Watts Monitor 2 Amps Max. 240 Watts Printer 3 Amps Max. 360 Watts Aux 1 2 Amps Max. 240 Watts Aux 2 3 Amps Max. 360 Watts Line Protection 15-Amp Circuit Breaker Transient Suppression (Common/Differential Modes) Energy (Max.) 50 Joules (10x1000 us Impulse) Peak Current 6,000 Amps (8x20 us Impulse) Suppression Voltage 500 volts (Line-to-Ground) (Neutral-to-Ground) 600 Volts (Line-to-Neutral) Transient Suppression of Modem and Phone Line (Tip to Ground/Ring to Ground protection) Energy 50 Joules Peak Current 6000 Amps Suppression Voltage 500 Volts Filtering Characteristics Common mode (Line-to-Ground) Outlet Output 5 dB @ 100 kHz, 25dB @5MHz 20 dB @ 500 KHz, 20 dB @ 10MHZ 40 dB @ 1 MHz, 5 dB @ 50 MHz Differential/Normal Mode(Line-to-Neutral) Outlet Output 5dB @ 100 kHz, 25 dB @ 5 MHz 25 dB @ 500kHz, 25 dB @ 10 MHz 50 dB @ 1 MHz, 15 dB @ 50 MHz Cord Length 10 feet Size 13 5/16 x 12 15/16 x 1 9/16 Inches (HWD) Weight 5 LBS 12 Oz (2.6 kg) (smc/jej-05/11/94)