40 MB SmartDrive AT (250-4123) Jumper Settings Faxback Doc. # 3090 Single-IDE Drive (DEFAULT): Dual-IDE Drive, Primary Drive: JUMPER SETTING JUMPER SETTING 1-2 ACT jumpered 1-2 ACT not jumpered 3-4 DSP not jumpered 3-4 DSP jumpered 5-6 C/D jumpered 5-6 C/D jumpered 7-8 HSP not jumpered 7-8 HSP not jumpered Dual-IDE Drive, Slave Drive: JUMPER SETTING 1-2 ACT jumpered all others not jumpered SUMMARY: JUMPER SETTING FUNCTION 1-2 ACT jumpered Provides signal to drive LED 7-8 HSP not Jumpered Reserved for future use. Jumpers 3-4 and 5-6 work in conjunction with each other. SINGLE SMARTDRIVE SYSTEM: JUMPER SETTING FUNCTION 1-2 ACT jumpered Indicates that the drive is the 5-6 C/D jumpered only SmartDrive installed (default). DAISY CHAIN, PRIMARY SMARTDRIVE: JUMPER SETTING FUNCTION 3-4 DSP jumpered Indicates that this is the PRIMARY 5-6 C/D jumpered drive in the Daisy Chain. Daisy Chain, Secondary SmartDrive: JUMPER SETTING FUNCTION 3-4 DSP not jumpered Indicates that this drive is the 5-6 C/D not jumpered second drive in the Daisy Chain. (dtc-07/29/93)