300 BPS Internal Modem (250-1003) Specifications Faxback Doc. # 4488 COMPATIBILITY: Tandy Protocol Modes RECEIVER SENSITIVITY: -40 dBm MODEM: Bell 103 (not Hayes TRANSMIT LEVEL: -13 dBm + 1 dB compatible) DIALING: Pulse, Tone DIALER: Tandy Command TONE DIAL LEVEL: N/A DATA RATES: 0-300 baud LINE IMPEDANCE: 600 Ohms SPEED SELECT: Automatic RINGER EQUIVALENCE: 0.7B CMD BUFFER: 25 digits SPEAKER: On 300 BAUD: Frequency Shift DATA FORMATS: 8 bit, 7 bit Keyed (FSK) even, odd, TESTING MODES: Local Analog no parity (abo-07/28/93)