RS-232 C Plus Upgrade Board (250-1014) Settings Faxback Doc. # 5171 Requires 25-1016 Adapter Board if not used on a Memory PLUS Expansion board. E 1-2 Com 2 Selected IRQ#3 PORT 2F8-2FF Hex (all versions) E 2-3 Com 1 Selected IRQ#4 PORT 3F8-3FF Hex (all versions)(+) International Version E 4-6, E 7-9 Domestic mode(+) E 4-5, E 7-8, E 9-10 International mode * NOTE - International mode allows modem to transmit at one baud rate while receiving at another. (+) denotes normal configuration Special mounting brackets for Tandy 1000EX/HX (AHC-0147 from national parts) (css 08/03/93)