Serial/Parallel Board (250-4034) Settings Faxback Doc. # 5486 Serial/Parallel Adapter (25-4034)* Short Board There are hardware modification for this board- 3000:017, 4000:008 Standard board, comes with the Tandy 3000/3000HD/4000 This board comes standard with a DB-25 female parallel printer port and a DB-9 male serial port ( default configuration ) E1-E3 selects USA Standard E1-E2 & E3-E4 International Standard E6-E7 selects LPT1 E5-E6 selects LPT2 E11-E12 IRQ7 - LPT1 E13-E14 IRQ5 - LPT2 E9-E10 selects COM1 E8-E9 selects COM2 E15-E16 IRQ4 - COM1 E17-E18 IRQ3 - COM2 (Only on Rev. B) LPT1 port address 378-37F Hex LPT2 port address 278-27F Hex COM1 port address 3F8-3FF Hex COM2 port address 2F8-2FF Hex Parallel Port (DB-25) 1 Strobe * 10 ACK * (*) denotes active LOW signal 2 Data Bit 0 11 BUSY 3 Data Bit 1 12 PE 4 Data Bit 2 13 SLCT 5 Data Bit 3 14 AUTO FEED * 6 Data Bit 4 15 ERROR * 7 Data Bit 5 16 INIT * 8 Data Bit 6 17 SLCT IN * 9 Data Bit 7 18-25 GND Serial Port (DB-9) Cable 26-269 converts DB-9 to DB-25 DB-9 Connector DB-25 Connector 1 Carrier Detect-------------- 8 2 Receive Data---------------- 3 3 Transmit Data--------------- 2 4 Data Terminal Ready--------- 20 5 Signal Ground--------------- 7 6 Data Set Ready-------------- 6 7 Req. To Send---------------- 4 8 Clear To Send--------------- 5 9 Ring Indicate--------------- 22 1. Check the position of the Baud-Rate Generator jumper. It is set at the factory to connect pins E1 and E3 for the USA Standard. To set the Baud-Rate Generator to the International Standard connect pins E1 and E2 with the jumper that connected E1 and E3. Then connect pins E3 and E4 with a second jumper. 2. If you are installing this board in the Tandy 3000, install a jumper on E5 and E6 to set the parallel port as Port 2 (LPT2). Install a jumper on E8 and E9 to set the serial port as Port 2 (COM2). 3. If you are installing this board in the Tandy 1000 or Tandy 1200, install a jumper on E5 and E6 to set the parallel port as Port 2. If a serial board is not already installed we suggest that you set the jumper on E9 and E10 to set the serial port as Port 1 (COM1). NOTE: The parallel port can be set as Port 1 (LPT1) by moving the jumper to connect pins E6 and E7. NOTE: In order to resolve interrupt conflicts with other boards, disable the corresponding interrupt on the Rev. B Serial/Parallel board by removing the jumper from the corresponding interrupt staking pins as follows: INTERRUPT STAKING PINS 7 E11-E12 5 E13-E14 4 E15-E16 3 E17-E18 Because of this, it is not recommended that 2 Rev. A Serial/Parallel Boards be used in a computer. (dkh/jej-05/12/94)