WP-2 Portable (260-3930) Battery Faxback Doc. # 5591 Word Processor The WP-2's internal backup battery is a CR2430 lithium battery (230-166). The life of the battery is about three years (without using expansion RAM). When the backup battery becomes weak, a warning is displayed and the entire screen blinks. Replace the battery immediately to prevent losing the contents of RAM. WARNING: Improper handling of the special lithium battery can cause a fire, explosion, or severe burns. Never recharge, disassemble, or heat the battery above 212'F (100'C). Never solder directly to the battery or expose the contents of the battery to water. Before replacing the backup battery, copy important files to cassette or diskette. Then proceed as follows: 1. Use the point of a pencil to turn off the memory-protect switch on the side of the unit. 2. Remove the backup battery cover and take out the old battery. 3. Insert the new battery observing the polarity symbol (-) marked inside the battery compartment. Be sure that the positive (+) side of the battery faces up. 4. Replace the compartment cover. 5. Turn on the memory-protect switch. CONNECTING THE WP-2 TO AN AC POWER SOURCE: By connecting the WP-2 Power Adapter (260-3804, optional/extra), the WP-2 can be operated when the Adapter is plugged into a 120VAC wall outlet. Before connecting the Adapter to the WP-2, be sure to turn the WP-2 and all peripherals OFF. To Connect the WP-2 to an AC Wall Outlet: 1. Connect the Adapter to an AC outlet. 2. Connect the Adapter to the DC6V Connector. (smm 08/04/93)