LP 6 (260-1166) Settings Faxback Doc. # 5942 SETTINGS Power Switch ON OnLine/OffLine Switch to ONLINE Set Dip Switch 1 Dip Switch 1 *=Standard Configuration (Parallel) OFF=OPEN CR=Carriage Return LF=Line Feed 1 * OPEN Normal Operation CLOSED Enables Selftest at OffLine State 2 * OPEN Carriage Return Does Linefeed CLOSED Carriage Return Does NOT Linefeed 3 OPEN Carriage Return Ignored After CR or LF * CLOSED Carriage Return NOT Ignored 4 * OPEN TANDY Characters CLOSED ASCII Characters INTERNAL DIP SWITCH SETTINGS: SWITCH SYMBOL On Off 1 Mode Test Normal 2 CR/NL CR CR+LF 3 NL/LF CR+LF LF 4 Char.Set Kana Ascii (dkh-08/04/93) (smm 08/26/93)