Safehouse Alarm (490-0470) Specifications Faxback Doc. # 8159 Exit Delay Control Time........................................0 - 45 sec adjustable Entry Delay Control Time.......................................0 - 40 sec adjustable Automatic Alarm Reset Time US/CA/AU/UK Models.................................................5 min. Continental European Model........................................50 sec. Trigger Resistance Loops 1, 2, 3, 4 and Panic Loop Normally Closed Loop Minimum resistance to trigger alarm ............................2.5 Kohms Maximum loop resistance when closed:.............................500 ohms Normally Open Loop Maximum resistance to trigger alarm:.............................500 ohms Minimum loop resistance when open:...............................50 Kohms Remote Switch Loop (N.O.) Maximum resistance to trigger alarm:..............................1 Kohms Minimum loop resistance when open:...............................50 Kohms Fire Loop (N.O.) Maximum resistance to trigger fire alarm:........................500 ohms Minimum resistance to trigger fire trouble alarm:................35 Kohms Minimum loop resistance when open:........................2.2 - 2.7 Kohms with ELM Note: Resistance value outside above ranges will cause unreliable operation. Response Time Loop 1, 2, 3, 4 & Panic:.............................................9 ms Remote, Fire, Fire-Trouble, Bypass sw & Reset button................50 ms Secondary AC Current Consumption...................................180 mA (at 120V AC, arm mode & without remote LED) Battery Current Consumption at 12 volt (AC Failed)..................70 mA (At arm mode & without remote LED) Power Requirements US/CA:...........................................................120V AC, 60 Hz, 50 W AU/UK:...........................................................240V AC, 50 Hz, 50 W Continental Europe:..............................................220V AC, 50 Hz, 50 W Terminals (Connected Terminals) Power AC Power........................................................37 and 38 (Transformer) Battery...................................................36 and 30 or 34 Detection Loop Loop 1 (Delayed): Normally Open.....................................................1 and 3 Normally Closed...................................................2 and 3 Loop 2 (Instant): Normally Open.....................................................3 and 5 Normally Closed...................................................3 and 4 Loop 3 (Instant): Normally Closed...................................................6 and 7 Loop 4 (Instant): Normally Closed...................................................7 and 8 Panic: Normally Open....................................................9 and 10 Fire: Normally Open...................................................27 and 28 with ELM Alarm Output Pre Alarm (For Loop 1 & 4) Regulated. 12V 50mA Max.............20 and 21 Fire Trouble Regulated. 12V 50 mA Max...........................31 and 32 Burglar Alarm Non-regulated 12V DC, 2A Max......................33 and 34 Power Output Accessory Power Regulated 12V DC 0.3A Max.......................22 and 23 Fire Detector Power Regulated 12V DC 0.3A Max...................29 and 30 Remote Station Remote key: Normally Open, Momentary............................11 and 12 ARM LED.........................................................12 and 13 LOOP LED........................................................12 and 14 Individual LOOP ARM LED Loop 1..........................................................15 and 19 Loop 2..........................................................16 and 19 Loop 3..........................................................17 and 19 Loop 4..........................................................18 and 19 10. Indicators AC POWER LED (Green) Lights when AC Power is present. MAIN ARM LED (Red) Lights in arm mode and blinks as an alarm memory. MAIN LOOP LED (Green) Lights when all loops are non-violated. Blinks what all loops are bypassed. BATTERY LED (Green) Lights when battery is enough. FIRE ALARM LED (Red) Lights when fire loop is violated. FIRE TROUBLE LED (Red) Lights when fire-wiring is open. Individual ARM LEDs (Red) Lights when bypass switch is in normal position, in arm mode. Blinks as an alarm memory. Individual LOOP LEDs (Green) Lights when loop is non-violated. Blinks when bypass switch is in bypass position. 11. Switches BURGLAR ALARM Test.........................................Momentary push FIRE ALARM Test/Restore:...................................Momentary push BATTERY TEST:..............................................Momentary push BYPASS (4 pcs):.....................................................Slide RESET:.....................................................Momentary push 12. Controls Exit DELAY TIME ADJUST........................................0 - 45 sec. Entry DELAY TIME ADJUST.......................................0 - 45 sec. Operating......................................................32F - 122F Temperature....................................................(0C - 50C) Storage.......................................................-40F - 149F Temperature..................................................(-40C - 65C) 15. Weight Unit........................................................6.6 lbs (3kg) Transformer US:.......................................................1.7 lbs (785 g) CA:.......................................................1.9 lbs (880 g) UK/Continental Europe:..................................................1.95 lbs (885 g) AU:.......................................................2.0 lbs (915 g) ELM:........................................................1.3 oz (38 g) 16. DIMENSIONS Unit:...................................13" (H) X 9 1/2" (W) X 3 3/4" (D) (330 (H) X 240 (W) X 95 (D) mm) Transformer:......................................3 3/4" (H) X 2 7/8" (D) (93 (H) X 74 (W) X 61 (D) mm) ELM:...................................3/4" (H) X 3 1/8" (W) X 1 1/2" (D) (20 (H) X 80 (W) X 37 (D) mm) (SMM/jlc-03/22/94)