Auto Ranging LCD Meter (220-0167) Specifications Faxback Doc. # 8203 Display.....................................................33/4 digit, LCD Ranges and Accuracy Maximum Frequency ........................................... 2 Khz +/- 12% DC Volts 300 mV-3V............................................+/-0.5% of reading and +/-0.2% of full scale, +/- in last digit 30-300-1000V.........................................+/-1.0% of reading and +/-0.2% of full scale, +/-1 in last digit (Maximum Measurement=1000 Volts) AC Volts 3-30-300-750V........................................+/-1.2% of reading and +/-0.5% of full scale +/-1 in last digit (Maximum Measurement=750 Volts RMS) DC Current 300 microA/30 mA........................................+/-1.0% reading and +/-0.2% of full scale, +/-1 in last digit 3000microA/300 mA.......................................+/-1.5% reading and +/-0.2% of full scale, +/-1 in last digit 10 A.................................................+/-2.0% of reading and +/-0.2% of full scale, +/-1 in last digit (Maximum Measurement=10 A) AC Current 300-3000 microA-30-300 mA......................... ..+/-2.5% of reading and +/-0.5% of full scale, +/-1 in last digit (Maximum Measurement=300 mA) 10 A.................................................+/-2.5% of reading and +/-0.5% of full scale, +/-1 in last digit Resistance 300 ohms-3-30-300 kohms..............................+/-1.0% of reading and +/-0.2% of full scale, +/-1 in last digit 3 M ohms.............................................+/-2.0% of reading and +/-0.2% of full scale, +/-1 in last digit 30 M ohms............................................+/-3.5% of reading and +/-0.5% of full scale, +/-1 in last digit Range.......................................Full auto range or manual range control for voltage and resistance measurements. Semi-auto and manual range for current measurements. Polarity..........................................Automatic, Minus sign for negative polarity Input Impedance........................................10 Megohm (DCV/ACV), more than 100 Megohm on 300 mV DC Continuity Function.......................................Continuity buzzer sounds at less than about 20 ohms Low Battery Indicator........................................."+/-" appears when battery voltage drops below Overrange Indication...........................0.L. appears on the display. Use care for DC 1000V, AC 750V, and DC/AC 10A ranges, as exceeding the maximum limits of these ranges can damage the meter and prevent an overrange indication. Operating Temperature.........................................32øF to 122øF (0øC to 50øC) Storage Temperature............................................4øF to 140øF (-20øC to 60øC) Power Source...............................................Two AA Batteries Power Consumption............................................5 mW (Typical) Dimensions.......................................31/16 X 61/2 X 13/8 Inches (78 X 165 X35 mm (WHD)) Weight........................................................20 Oz (566 g) Accessories............................................Fuse,Test leads with 90 degrees plug, Holster (RLR-09/29/93)