Wireless Home (490-2010) System Indicators Faxback Doc. # 8924 Alarm System UNDERSTANDING THE SYSTEM INDICATORS During normal operation (when the system is armed or disarmed), the base's top panel shows the status of the zones and warns you about low batteries and other problems. To view the zone and status indicators, lift the top panel as shown. The information in the following chart describes the function of each indicator. Indicator Status Meaning --------------------------------------------------------------------------- Off No transmitter for this zone ZONE On No violations for this zone; battery OK Slow flash Zone violated Fast flash Transmitter missing or low battery --------------------------------------------------------------------------- Flash red Armed with violations STATUS Steady red Armed with no violations Flash green Disarmed with violations Steady green Disarmed with no violations --------------------------------------------------------------------------- Off AC power OK; no low batteries BATT LOW Steady on No AC power Flashing Batteries in base or transmitter(s) are low --------------------------------------------------------------------------- MISSING Off No transmitter(s) missing On Transmitter(s) missing --------------------------------------------------------------------------- Off No fire reported by siren detector FIRE Flashing Fire reported by siren detector --------------------------------------------------------------------------- Off System not armed in Home mode HOME On System armed in Home mode --------------------------------------------------------------------------- Off System not armed in Away mode AWAY On System armed in Away mode --------------------------------------------------------------------------- Off Day mode not activated DAY On Day mode activated --------------------------------------------------------------------------- Off System not in learn mode On System in learn mode LEARN Flashing You must enter your personal access code for the base to enter the learn mode --------------------------------------------------------------------------- Off System not in code learning mode CODE On System in code learning mode --------------------------------------------------------------------------- Off No zones bypassed BYPASS On Zones bypassed Flashing A zone is currently violated and can be bypassed --------------------------------------------------------------------------- Off System not in Test mode TEST On System in Test mode --------------------------------------------------------------------------- POWER Off AC power not connected On AC power connected --------------------------------------------------------------------------- Indicators During a Power Failure If a power failure occurs, the base continues to operate as long as you installed batteries in the base and the batteries are still good. To conserve battery power, the base turns off all indicators except STATUS and BATT LOW. Pressing any button turns on the rest of the indicators for about 1 minute so you can view the status and operate the system. (SMC/jlc-03/22/94)